Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Inspection Procedure
This troubleshooting procedure is based on the premise that the engine is started. If the engine is not started, proceed to the (See PROBLEM SYMPTOMS TABLE ).
- PERFORM ACTIVE TEST USING TECHSTREAM (FUEL PUMP)Ā
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG) and turn the Techstream on.
- Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump / Speed.
- Check whether operating sounds can be heard while operating the fuel pump using the Techstream.
OK: Operating sounds can be heard from fuel pump.Ā
NG:Ā Go to StepĀ Ā 5
OK: Go to next stepĀ
- CHECK HARNESS AND CONNECTOR (FUEL PUMP ECU - ECM, BODY GROUND)Ā
- Disconnect the N2 fuel pump ECU connector.
- Disconnect the A38 ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard ResistanceĀ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition N2-5 (FPC) - A38-52 (FPC) Always Below 1 Ω N2-4 (DI) - A38-18(DI) Always Below 1 Ω N2-6 (E) - Body ground Always Below 1 Ω N2-5 (FPC) or A38-52 (FPC) - Body ground Always 10 kΩ or higher N2-4 (DI) or A38-18 (DI)-Body ground Always 10 kΩ or higher M2-1 (FP-) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTORĀ
OK: Go to next stepĀ
- REPLACE FUEL PUMP ECUĀ
- Replace the fuel pump ECU (See REMOVAL ).
- CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIREDĀ
- Check the fuel pump operation.
OK: Malfunction has been repaired successfully.Ā
NG: REPLACE ECMĀ (See ECMĀ )
OK: ENDĀ
- Check the fuel pump operation.
- INSPECT CIRCUIT OPENING RELAY (C/OPN)Ā
- Remove the circuit opening relay (C/OPN) from the engine room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard ResistanceĀ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 3 - 5 No battery voltage applied to terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω
NG: REPLACE CIRCUIT OPENING RELAY (C/OPN)Ā
OK: Go to next stepĀ
- INSPECT CIRCUIT OPENING RELAY (POWER SOURCE VOLTAGE)Ā
- Remove the circuit opening relay (C/OPN) from the engine room relay block.
- Turn the engine switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard VoltageĀ
STANDARD VOLTAGE SPECIFICATIONTester Connection Switch Condition Specified Condition C/OPN relay (2) - Body ground Engine switch on (IG) 11 to 14 V C/OPN relay (5) - Body ground Engine switch on (IG) 11 to 14 V
NG:Ā Go to StepĀ Ā 13
OK: Go to next stepĀ
- CHECK HARNESS AND CONNECTOR (CIRCUIT OPENING RELAY - ECU, FUEL PUMP ECU)Ā
- Remove the circuit opening relay (C/OPN) from the engine room relay block.
- Disconnect the A38 ECM connector.
- Disconnect the N2 fuel pump ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard ResistanceĀ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition C/OPN relay (1)-A38-48 (FC) Always Below 1 Ω C/OPN relay (3) - N2-3 (+B) Always Below 1 Ω C/OPN relay (1) or A38-48 (FC) - Body ground Always 10 kΩ or higher C/OPN relay (3) or N2-3 (+B) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTORĀ
Courtesy of Ā© TOYOTA, LICENSE AGREEMENT TMS1002
OK: Go to next stepĀ
- CHECK HARNESS AND CONNECTOR (FUEL PUMP - FUEL PUMP ECU)Ā
- Disconnect the N1 fuel pump connector.
- Disconnect the N2 fuel pump ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard ResistanceĀ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition N1-4 (B2) - N2-2 (FP) Always Below 1 Ω N1-5 (E2) - N2-1 (FP-) Always Below 1 Ω N1-4 (B2) or N2-2 (FP) - Body ground Always 10 kΩ or higher N1-5 (E2) or N2-1 (FP-) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTORĀ
Courtesy of Ā© TOYOTA, LICENSE AGREEMENT TMS1002
OK: Go to next stepĀ
- INSPECT FUEL PUMPĀ
- Inspect the fuel pump (See REMOVAL ).
NG: REPLACE FUEL PUMPĀ (See REMOVAL )
OK: Go to next stepĀ
- CHECK HARNESS AND CONNECTOR (FUEL PUMP ECU - ECM, BODY GROUND)Ā
- Disconnect the N2 fuel pump ECU connector.
- Disconnect the A38 ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard ResistanceĀ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition N2-5 (FPC) - A38-52 (FPC) Always Below 1 Ω N2-4 (DI) - A38-18 (DI) Always Below 1 Ω N2-6 (E) - Body ground Always Below 1 Ω N2-5 (FPC) or A38-52 (FPC) - Body ground Always 10 kΩ or higher N2-4 (DI) or A38-18 (DI) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTORĀ
Courtesy of Ā© TOYOTA, LICENSE AGREEMENT TMS1002
OK: Go to next stepĀ
- REPLACE FUEL PUMP ECUĀ
- Replace the fuel pump ECU (See REMOVAL ).
- CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIREDĀ
- Check the fuel pump operation.
OK: Malfunction has been repaired successfully.Ā
NG: REPLACE ECMĀ (See ECMĀ )
OK: ENDĀ
- Check the fuel pump operation.
- CHECK HARNESS AND CONNECTOR (CIRCUIT OPENING RELAY - EFI NO. 2 RELAY, IGN FUSE)Ā
- Remove the circuit opening relay (C/OPN) from the engine room relay block.
- Remove the EFI NO. 2 relay (EFI NO. 2) from the engine room relay block.
- Remove the IGN fuse from the engine room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard ResistanceĀ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition C/OPN relay (2) - IGN fuse (2) Always Below 1 Ω C/OPN relay (5) - EFI NO. 2 relay (3) Always Below 1 Ω C/OPN relay (2) or IGN fuse (2) - Body ground Always 10 kΩ or higher C/OPN relay (5) or EFI NO. 2 relay (3) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTORĀ
Courtesy of Ā© TOYOTA, LICENSE AGREEMENT TMS1002
OK: Go to next stepĀ
- INSPECT EFI NO. 2 RELAY (EFI NO. 2)Ā
- Remove the EFI NO. 2 relay (EFI NO. 2) from the engine room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard ResistanceĀ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 3 - 5 No battery voltage applied to terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω
NG: REPLACE EFI NO. 2 RELAY (EFI NO. 2)Ā
OK: Go to next stepĀ
- CHECK HARNESS AND CONNECTOR (EFI NO. 2 RELAY - INTEGRATION RELAY, BATTERY AND BODY GROUND)Ā
- Remove the EFI MAIN 2 fuse from the engine room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard ResistanceĀ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition EFI MAIN 2 fuse Always Below 1 Ī© - Reinstall the EFI MAIN 2 fuse.
- Remove the EFI NO. 2 relay (EFI NO. 2) from the engine room relay block.
- Remove the integration relay from the engine room relay block.
- Disconnect the 1B integration relay connector.
- Disconnect the cable from the positive (+) battery terminal.
- Measure the resistance according to the value(s) in the table below.
Standard ResistanceĀ
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition EFI NO. 2 relay (1) - 1B-4 Always Below 1 Ω EFI NO. 2 relay (5) - Positive (+) battery cable Always Below 1 Ω EFI NO. 2 relay (2) - Body ground Always Below 1 Ω EFI NO. 2 relay (1) or 1B-4 - Body ground Always 10 kΩ or higher EFI NO. 2 relay (5) or Positive (+) battery cable - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTORĀ
Courtesy of Ā© TOYOTA, LICENSE AGREEMENT TMS1002
OK: GO TO ECM POWER SOURCE CIRCUITĀ (See ECM POWER SOURCE CIRCUITĀ )
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- ⢠You smell fuel, burning insulation, or see smoke.
- ⢠Brakes feel soft, pull hard to one side, or make grinding noises.
- ⢠The engine overheats, stalls repeatedly, or misfires under load.
- ⢠You are missing required tools, torque specs, or safe lifting equipment.
- ⢠You are not confident in the next step or safety outcome.