2008 Toyota Corolla CE, AutomaticFACTORY OEM SERVICE PROCEDURE

Inspection Procedure

  1. PERFORM ACTIVE TEST BY TECHSTREAM (OPERATION OF CIRCUIT OPENING RELAY) 
    1. Connect Techstream to the DLC3.
    2. Turn the ignition switch to the ON position and turn the tester on.
    3. Select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump / Speed.
    4. Check whether operating sounds can be heard while operating the relay using the tester.

      OK: 

      Operating sounds can be heard from relay. 

    OK:  Go to step  7

    NG: Go to next step 

  2. INSPECT ECM POWER SOURCE CIRCUIT 
    1. Inspect the ECM power source circuit (See ECM POWER SOURCE CIRCUIT  ).

    NG: REPAIR OR REPLACE ECM POWER SOURCE CIRCUIT 

    OK: Go to next step 

  3. INSPECT CIRCUIT OPENING RELAY 
    1. Remove the C/OPN relay from the instrument panel J/B.
    2. Check the C/OPN relay resistance.

      Standard resistance 

      RESISTANCE SPECIFIED CONDITION

      Tester Connections Specified Conditions
      3 - 5 10 kΩ or higher
      3 - 5 Below 1 Ω (when battery voltage applied to terminals 1 and 2)
      Fig 1: Identifying Circuit Opening Relay
      G05192682Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. Reinstall the circuit opening relay.

    NG: REPLACE CIRCUIT OPENING RELAY 

    OK: Go to next step 

  4. INSPECT ECM (FC VOLTAGE) 
    1. Turn the ignition switch to the ON position.
    2. Measure the voltage between the terminals of the E3 and E6 ECM connectors.

      Standard voltage 

      VOLTAGE SPECIFIED CONDITION

      Tester Connections Specified Conditions
      FC (E6-10) - E1 (E3-5) Between 9 V and 14 V
      Fig 2: Inspecting ECM (FC Voltage)
      G05192683Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    OK: REPLACE ECM 

    NG: Go to next step 

  5. CHECK HARNESS AND CONNECTOR (IGNITION SWITCH - CIRCUIT OPENING RELAY) 
    1. Disconnect the 110 ignition switch connector.
    2. Fig 3: Identifying 110 Ignition Switch Connector And C/OPN Relay
      G05192684Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. Remove the C/OPN relay from the instrument panel J/B.
    4. Check the resistance.

      Standard resistance (Check for open) 

      RESISTANCE SPECIFIED CONDITION - CHECK FOR OPEN

      Tester Connections Specified Conditions
      IG2 (110-6) - Instrument panel J/B (Circuit opening relay terminal 1) Below 1 Ω

      Standard resistance (Check for short) 

      RESISTANCE SPECIFIED CONDITION - CHECK FOR SHORT

      Tester Connections Specified Conditions
      IG2 (110-6) or Instrument panel J/B (Circuit opening relay terminal 1) - Body ground 10 kΩ or higher
    5. Reinstall the C/OPN relay.
    6. Reconnect the ignition switch connector.

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  6. CHECK HARNESS AND CONNECTOR (ECM - CIRCUIT OPENING RELAY) 
    1. Disconnect the E6 ECM connector.
    2. Fig 4: Identifying E6 ECM Connector And C/OPN Relay
      G05192685Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. Remove the C/OPN relay from the instrument panel J/B.
    4. Check the resistance.

      Standard resistance (Check for open) 

      RESISTANCE SPECIFIED CONDITION - CHECK FOR OPEN

      Tester Connections Specified Conditions
      FC (E6-10) - Instrument panel J/B (Circuit opening relay terminal 2) Below 1 Ω

      Standard resistance (Check for short) 

      RESISTANCE SPECIFIED CONDITION - CHECK FOR SHORT

      Tester Connections Specified Conditions
      FC (E6-10) or Instrument panel J/B (Circuit opening relay terminal 2) - Body ground 10 kΩ or higher
    5. Reinstall the C/OPN relay.
    6. Reconnect the ECM connector.

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: REPLACE ECM 

  7. INSPECT FUEL PUMP 
    1. Inspect the fuel pump (See INSPECTION ).

    NG: REPLACE FUEL PUMP 

    OK: Go to next step 

  8. CHECK HARNESS AND CONNECTOR (CIRCUIT OPENING RELAY - FUEL PUMP, FUEL PUMP - BODY GROUND) 
    1. Remove the C/OPN relay from the instrument panel J/B.
    2. Disconnect the F10 fuel pump connector.
    3. Fig 5: Checking Harness And Connector (Circuit Opening Relay - Fuel Pump, Fuel Pump - Body Ground)
      G05192686Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    4. Check the resistance.

      Standard resistance (Check for open) 

      RESISTANCE SPECIFIED CONDITION - CHECK FOR OPEN

      Tester Connections Specified Conditions
      Instrument panel J/B (Circuit opening relay terminal 3) - Fuel pump (F10-4) Below 1 Ω
      Fuel pump (F10-5) - Body ground Below 1 Ω

      Standard resistance (Check for short) 

      RESISTANCE SPECIFIED CONDITION - CHECK FOR SHORT

      Tester Connections Specified Conditions
      Instrument panel J/B (Circuit opening relay terminal 3) or Fuel pump (F10-4) - Body ground 10 kΩ or higher
    5. Reconnect the fuel pump connector.
    6. Reinstall the C/OPN relay.

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: CHECK AND REPAIR HARNESS AND CONNECTOR (EFI RELAY - CIRCUIT OPENING RELAY) 

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.