Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Inspection Procedure
- PERFORM ACTIVE TEST USING INTELLIGENT TESTER (FUEL PUMP/SPD)Â
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch ON and turn the tester ON.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / FUEL PUMP / SPD.
- Check whether the fuel pump operating sound occurs when performing the Active Test on the tester.
OK: Fuel pump operating sound occurs.Â
OK: GO to step  12
NG: GO to Next StepÂ
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (C/OPN RELAY INPUT VOLTAGE)Â
- Measure the voltage between the terminal of the instrument panel junction block and the body ground when the ignition switch is turned ON and OFF.
Standard voltageÂ
TESTER CONNECTION IGNITION SWITCH CONDITIONTester Connection Ignition Switch Condition Specified Condition IB-11 - Body ground OFF Below 1 V IF-4 - Body ground IB-11 - Body ground ON 9 to 14 V IF-4 - Body ground OK: GO to step  4
NG: GO to Next StepÂ
- CHECK WIRE HARNESS (INSTRUMENT PANEL JUNCTION BLOCK - INTEGRATION RELAY AND IG2 RELAY)Â
- Remove the integration relay and IG2 relay from the engine room No. 1 relay block.
- Disconnect the instrument panel junction block connector.
- Measure the resistance.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition IG2 relay 5 - IF-4 Below 1 Ω 1A-4 - IB-11 Below 1 Ω IF-4 - Body ground 10 kΩ or higher IB-11 - Body ground 10 kΩ or higher - Reinstall the integration relay and IG2 relay.
- Reconnect the instrument panel junction block connector.
NG: REPAIR OR REPLACE HARNESS AND CONNECTORÂ
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: GO TOÂ ECM POWER SOURCE CIRCUITÂ
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (C/OPN RELAY)Â
- Remove the instrument panel junction block.
- Measure the C/OPN relay resistance.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition IB-11 - IA-8 10 kΩ or higher Below 1 Ω (when battery voltage is applied to terminals IF-4 and IE-5) HINT:
Relay coil circuit between IF-4 and IE-5 is through IGN fuse.
- Reinstall the instrument panel junction block.
NG: REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLYÂ
OK: GO to Next StepÂ
- CHECK WIRE HARNESS (INSTRUMENT PANEL JUNCTION BLOCK - ECM)Â
- Disconnect the A9 ECM connector.
- Disconnect the IE connector from the instrument panel junction block.
- Measure the resistance.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition IE-5 - A9-7 (FC) Below 1 Ω IE-5 or A9-7 (FC) - Body ground 10 kΩ or higher - Reconnect the instrument panel junction block and the ECM connectors.
NG: REPAIR OR REPLACE HARNESS AND CONNECTORÂ
OK: GO to Next StepÂ
- PERFORM ACTIVE TEST USING INTELLIGENT TESTER (FUEL PMP SP CTL)Â
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch ON and turn the tester ON.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / FUEL PMP SP CTL.
- Check the operation of the relay while operating it using the intelligent tester.
OK: Operating noise can be heard from the relay.Â
OK: GO to step  9
NG: GO to Next StepÂ
- INSPECT F/PMP RELAYÂ
(see
INSPECTION PROCEDUREÂ )
NG: REPLACE F/PMP RELAYÂ
OK: GO to Next StepÂ
- CHECK WIRE HARNESS (F/PMP RELAY - ECM AND INSTRUMENT PANEL JUNCTION BLOCK)Â
- Remove the F/PMP relay from the engine room No. 1 relay block.
- Disconnect the B30 ECM connector.
- Disconnect the IA instrument panel junction block connector.
- Measure the resistance.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition F/PMP relay terminal 1 - B30-59 (FPR) Below 1 Ω F/PMP relay terminal 2 - IA-8 Below 1 Ω F/PMP relay terminal 3 - IA-8 Below 1 Ω F/PMP relay terminal 1 or B30-59 (FPR) - Body ground 10 kΩ or higher F/PMP relay terminal 2 or IA-8 - Body ground 10 kΩ or higher F/PMP relay terminal 3 or IA-8 - Body ground 10 kΩ or higher - Reconnect the ECM connector
- Reconnect the instrument panel junction block connector.
- Reinstall the F/PMP relay.
NG: REPAIR OR REPLACE HARNESS AND CONNECTORÂ
OK: GO to Next StepÂ
- CHECK WIRE HARNESS (F/PMP - FUEL PUMP AND PUMP RESISTOR)Â
- Remove the F/PMP relay from the engine room No. 1 relay block.
- Disconnect the S1 fuel pump connector.
- Disconnect the A20 fuel pump resistor connector.
- Measure the resistance.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition F/PMP relay terminal 4 - S1-4 Below 1 Ω F/PMP relay terminal 5 - A20-1 Below 1 Ω A20-2 - S1-4 Below 1 Ω S1-5 - Body ground Below 1 Ω F/PMP relay terminal 4 or S1 -4 - Body ground 10 kΩ or higher F/PMP relay terminal 5 or A20-1 - Body ground 10 kΩ or higher A20-2 or S1-4 - Body ground 10 kΩ or higher - Reconnect the fuel pump resistor connector.
- Reconnect the fuel pump connector.
- Reinstall the F/PMP relay.
NG: REPAIR OR REPLACE HARNESS AND CONNECTORÂ
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: GO to Next StepÂ
- INSPECT FUEL PUMPÂ
- Inspect fuel pump resistance.
- Measure the resistance between the terminals.
Standard resistance: 0.2 to 3.0 Ω at 20°C(68°F)Â
- Inspect fuel pump operation.
- Apply the battery voltage to both the terminals. Check that the pump operates.NOTE:
- These tests must be done quickly (within 10 seconds) to prevent the coil from burning out.
- Keep the fuel pump as far away from the battery as possible.
- Always turn the voltage on and off on the battery side, not the fuel pump side.
- Apply the battery voltage to both the terminals. Check that the pump operates.
NG: REPLACE FUEL PUMPÂ
OK: GO to Next StepÂ
- Inspect fuel pump resistance.
- INSPECT FUEL PUMP RESISTORÂ
- Measure the resistance of the fuel pump resistor.
Standard resistance: 0.30 to 0.34 Ω at 20°C (68°F)Â
NG: REPLACE FUEL PUMP RESISTORÂ
OK: REPLACE ECMÂ
- READ VALUE USING INTELLIGENT TESTER (STARTER SIG)Â
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch ON and turn the tester ON.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / STARTER SIG.
- Check the result when the ignition switch is turned ON and START.
OKÂ
DATA LISTIgnition Switch Position STARTER SIG ON OFF START ON NG: REPAIR OR REPLACE STARTING SYSTEMÂ
OKÂ
- READ VALUE USING INTELLIGENT TESTER (ENGINE SPD)Â
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch ON and turn the tester ON.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / PRIMARY / ENGINE SPD.
- Read the values displayed on the tester while cranking.
Standard: Values are displayed continuously.Â
NG: REPAIR OR REPLACE CRANKSHAFT POSITION SENSOR CIRCUITÂ
OK: REPLACE ECMÂ
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.