2007 Toyota RAV4 Base, 2.4 D, AWDFACTORY OEM SERVICE PROCEDURE

On-Vehicle Inspection

  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL 
    CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
  2. INSPECT INSTRUMENT PANEL JUNCTION BLOCK 
    NOTE: The circuit opening relay is built into the instrument panel junction block.
    1. Measure the resistance between the terminals.
    Fig 1: Identifying Instrument Panel Junction Block
    G05183859Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    Standard resistance 

    TESTER CONNECTION SPECIFIED CONDITION

    Tester Connection Specified Condition
    1B-11 - 1A-8 10 kΩ or higher
    1B-11 - 1A-8 Below 1 Ω (when battery voltage is applied to terminals 1E-5 and 1D-1)

    If the result is not as specified, replace the instrument panel junction block.

  3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL 