2007 Toyota Prius BaseFACTORY OEM SERVICE PROCEDURE

Service Data

SERVICE DATA REFERENCE

Battery plug Resistance between terminals 10 kΩ or higher
Install the service grip:
Resistance between terminals
Below 1 Ω
No. 1 system main relay Positive terminal - Negative terminal 10 kΩ or higher
A-2 (CONT2) - B-2 (CONT2) Below 1 Ω
A-3 (CONT3) - C-2 (CONT3) Below 1 Ω
B-1 (GND) - GND Below 1 Ω
C-1 (GND) - GND Below 1 Ω
Apply battery voltage between the GND terminal and CONT1 terminal of the connector A:
Positive terminal - Negative terminal
Below 1 Ω
A-1 (CONT1) - GND 70 to 160 kΩ
No. 2 system main relay Positive terminal - Negative terminal 10 kΩ or higher
Apply battery voltage between the connector terminals:
Positive terminal - Negative terminal
Below 1 Ω
Resistance between the connector terminals 20 to 50 kΩ
No. 3 system main relay Positive terminal - Negative terminal 10 kΩ or higher
Apply battery voltage between the connector terminals:
Positive terminal - Negative terminal
Below 1 Ω
Resistance between the connector terminals 20 to 50 kΩ
System main resistor Resistance between terminals 18 to 22 Ω
Battery blower relay 3 - 5 10 kΩ or higher
When battery voltage is applied to terminals 1 and 2:
3 - 5
Below 1 Ω
Battery current sensor Positive probe to terminal 1 (VIB) Negative probe to terminal 2 (GIB) 3.5 to 4.5 kΩ
Positive probe to terminal 2 (GIB) Negative probe to terminal 1 (VIB) 5 to 7 kΩ
Positive probe to terminal 1 (VIB) Negative probe to terminal 3 (IB) A083579E02 3.5 to 4.5 kΩ
Positive probe to terminal 1 (VIB) Negative probe to terminal 3 (IB) 5 to 7 kΩ
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.