2007 Toyota Highlander Hybrid, FWDFACTORY OEM SERVICE PROCEDURE

SFI System: Precaution

NOTE: When disconnecting the negative (-) battery cable, initialize the following systems after the terminal is reconnected.
SYSTEM REFERENCE

System See Procedure
SFI System BASIC INSPECTION 
Power Window Control System INITIALIZATION
  1. PRECAUTIONS FOR INSPECTING HYBRID CONTROL SYSTEM 
    1. Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
      NOTE: Do not put the vehicle into the READY-on state with the service plug grip removed as this may cause a malfunction.
    2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.
      Fig 1: Disconnecting Service Plug Grip
      G05201143Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      HINT:

      At least 5 minutes are required to discharge the high-voltage capacitor inside the with converter inverter assembly.

    3. After removing the inverter cover, wrap the interlock round terminal for the inverter cover with vinyl tape to prevent it from shorting to ground.
      Fig 2: Wrapping Interlock Round Terminal For Inverter Cover With Vinyl Tape
      G05199968Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.