Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Inspection Procedure
When using intelligent tester:Â
- PERFORM ACTIVE TEST BY INTELLIGENT TESTER (OPERATION OF CIRCUIT OPENING RELAY)Â
- Connect an intelligent tester to the DLC3.
- Turn the ignition switch to ON and turn the tester ON.
- Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / FUEL PUMP/ SPD.
- Check whether operating sounds can be heard while operating the relay using the tester.
OK:Â
Operating sounds can be heard from relay.Â
OK: Go to step  7
NG: Go to next stepÂ
- INSPECT ECM POWER SOURCE CIRCUITÂ
- Inspect the ECM power source circuit (See ECM POWER SOURCE CIRCUITÂ ).
NG: REPAIR OR REPLACE ECM POWER SOURCE CIRCUITÂ
OK: Go to next stepÂ
- INSPECT CIRCUIT OPENING RELAYÂ
- Remove the C/OPN relay from the instrument panel J/B.
- Check the C/OPN relay resistance.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions 3 - 5 10 kΩ or higher 3 - 5 Below 1 Ω (when battery voltage applied to terminals 1 and 2) - Reinstall the circuit opening relay.
NG: REPLACE CIRCUIT OPENING RELAYÂ
OK: Go to next stepÂ
- INSPECT ECM (FC VOLTAGE)Â
- Turn the ignition switch to ON.
- Measure the voltage between the terminals of the E3 and E6 ECM connectors.
Standard voltageÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions FC (E6-10) - E1 (E3-5) Between 9 V and 14 V OK: REPLACE ECMÂ
NG: Go to next stepÂ
- CHECK HARNESS AND CONNECTOR (IGNITION SWITCH - CIRCUIT OPENING RELAY)Â
- Disconnect the 110 ignition switch connector.
- Remove the C/OPN relay from the instrument panel J/B.
- Check the resistance.
Standard resistance (Check for open)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions IG2 (I10-6) - Instrument panel J/B (Circuit opening relay terminal 1) Below 1 Ω Standard resistance (Check for short)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions IG2 (I10-6) or Instrument panel J/B (Circuit opening relay terminal 1) - Body ground 10 kΩ or higher - Reinstall the C/OPN relay.
- Reconnect the ignition switch connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: Go to next stepÂ
- CHECK HARNESS AND CONNECTOR (ECM - CIRCUIT OPENING RELAY)Â
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
- Disconnect the E6 ECM connector.
- Remove the C/OPN relay from the instrument panel J/B.
- Check the resistance.
Standard resistance (Check for open)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions FC (E6-10) - Instrument panel J/B (Circuit opening relay terminal 2) Below 1 Ω Standard resistance (Check for short)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions FC (E6-10) or Instrument panel J/B (Circuit opening relay terminal 2) - Body ground 10 kΩ or higher - Reinstall the C/OPN relay.
- Reconnect the ECM connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: REPLACE ECMÂ
- INSPECT FUEL PUMPÂ
- Inspect the fuel pump (See INSPECTION ).
NG: REPLACE FUEL PUMPÂ
OK: Go to next stepÂ
- CHECK HARNESS AND CONNECTOR (CIRCUIT OPENING RELAY - FUEL PUMP, FUEL PUMP - BODY GROUND)Â
- Remove the C/OPN relay from the instrument panel J/B.
- Disconnect the F10 fuel pump connector.
- Check the resistance.
Standard resistance (Check for open)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions Instrument panel J/B (Circuit opening relay terminal 3) - Fuel pump (F10-4) Below 1 Ω Fuel pump (F10-5) - Body ground Below 1 Ω Standard resistance (Check for short)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions Instrument panel J/B (Circuit opening relay terminal 3) or Fuel pump (F10-4) - Body ground 10 kΩ or higher - Reconnect the fuel pump connector.
- Reinstall the C/OPN relay.
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: CHECK AND REPAIR HARNESS AND CONNECTOR (EFI RELAY - CIRCUIT OPENING RELAY)Â
When Using OBD II Scan Tool:Â
- CHECK FUEL PUMP (OPERATION)Â
- Turn the ignition switch to ON.
- Connect terminals FC and E1 of the ECM connector.
- Check for fuel pressure in the fuel inlet hose when it is pinched off.
OK:Â
There is pressure in fuel inlet hose.Â
HINT:
At this time, operating sounds can be heard from the fuel pump.
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLEÂ
NG: Go to next stepÂ
- INSPECT ECM POWER SOURCE CIRCUITÂ
- Inspect the ECM power source circuit (See ECM POWER SOURCE CIRCUITÂ ).
NG: REPAIR OR REPLACE ECM POWER SOURCE CIRCUITÂ
OK: Go to next stepÂ
- INSPECT CIRCUIT OPENING RELAYÂ
- Remove the C/OPN relay from the instrument panel J/B.
- Check the C/OPN relay resistance.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions 3 - 5 10 kΩ or higher 3 - 5 Below 1 Ω (when battery voltage is applied to terminals 1 and 2) - Reinstall the circuit opening relay.
NG: REPLACE CIRCUIT OPENING RELAYÂ
OK: Go to next stepÂ
- INSPECT ECM (FC VOLTAGE)Â
- Turn the ignition switch to ON.
- Measure the voltage between the terminals of the E3 and E6 ECM connectors.
Standard voltageÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions FC (E6-10) - E1 (E3-5) Between 9 V and 14 V OK: REPLACE ECMÂ
NG: Go to next stepÂ
- CHECK HARNESS AND CONNECTOR (IGNITION SWITCH - CIRCUIT OPENING RELAY)Â
- Disconnect the 110 ignition switch connector.
- Remove the C/OPN relay from the instrument panel J/B.
- Check the resistance.
Standard resistance (Check for open)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions IG2 (I10-6) - Instrument panel J/B (Circuit opening relay terminal 1) Below 1 Ω Standard resistance (Check for short)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions IG2 (I10-6) or Instrument panel J/B (Circuit opening relay terminal 1) - Body ground 10 kΩ or higher - Reinstall the C/OPN relay.
- Reconnect the ignition switch connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: Go to next stepÂ
- CHECK HARNESS AND CONNECTOR (ECM - CIRCUIT OPENING RELAY)Â
- Disconnect the E6 ECM connector.
- Remove the C/OPN relay from the instrument panel J/B.
- Check the resistance.
Standard resistance (Check for open)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions FC (E6-10) - Instrument panel J/B (Circuit opening relay terminal 2) Below 1 Ω Standard resistance (Check for short)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions FC (E6-10) or Instrument panel J/B (Circuit opening relay terminal 2) - Body ground 10 kΩ or higher - Reinstall the C/OPN relay.
- Reconnect the ECM connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: Go to next stepÂ
- INSPECT FUEL PUMPÂ
- Inspect the fuel pump (See INSPECTION ).
NG: REPLACE FUEL PUMPÂ
OK: Go to next stepÂ
- CHECK HARNESS AND CONNECTOR (CIRCUIT OPENING RELAY - FUEL PUMP, FUEL PUMP - BODY GROUND)Â
- Remove the circuit opening relay from the instrument panel J/B.
- Disconnect the F10 fuel pump connector.
- Check the resistance.
Standard resistance (Check for open)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions Instrument panel J/B (Circuit opening relay terminal 3) - Fuel pump(F10-4) Below 1 Ω Fuel pump (F10-5) - Body ground Below 1 Ω Standard resistance (Check for short)Â
TESTER CONNECTION SPECIFIED CONDITIONTester Connections Specified Conditions Instrument panel J/B (Circuit opening relay terminal 3) or Fuel pump (F10-4) - Body ground 10 kΩ or higher - Reconnect the fuel pump connector.
- Reinstall the C/OPN relay.
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: CHECK AND REPAIR HARNESS AND CONNECTOR (EFI RELAY - CIRCUIT OPENING RELAY)Â
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.