Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2006 Toyota Avalon XLSFACTORY OEM SERVICE PROCEDURE
Inspection Procedure
- INSPECT POWER WINDOW REGULATOR MOTOR (DRIVER SIDE)
- Remove the power window motor.
- Apply battery voltage to the motor connector according to POWER WINDOW REGULATOR MOTOR (DRIVER SIDE)
.NOTE: Do not apply battery voltage to any terminals except terminal 1 and 2.
Standard
POWER WINDOW REGULATOR MOTOR (DRIVER SIDE)Measurement Condition Specified Condition Battery positive (+) -> Terminal 2 (U)
Battery negative (-) -> Terminal 1 (D)Motor gear rotates clockwise Battery positive (+) -> Terminal 1 (D)
Battery negative (-) -> Terminal 2 (U)Motor gear rotates counterclockwise
NG: REPLACE POWER WINDOW REGULATOR MOTOR (DRIVER SIDE)
OK: Go to next step
- CHECK WIRE HARNESS (WINDOW REGULATOR MOTOR - MULTIPLEX NETWORK MASTER SWITCH)
- Disconnect the I4 and I6 connectors.
- Measure the resistance of the wire harness side connectors.
Resistance
WINDOW REGULATOR MOTOR - MULTIPLEX NETWORK MASTER SWITCHTester Connection Condition Specified Condition I4-1 - I6-9 Always Below 1 Ω I4-2 - I6-4 Always Below 1 Ω I4-1 - Body ground Always 10 kΩ or higher I4-2 - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.