Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Charging System: Generator: Installation
- INSTALL GENERATOR
- Install the generator with the 2 bolts.
Torque:
52 N.m (530 kgf.cm, 38 ft.lbf) for bolt A
21 N.m (214 kgf.cm, 15 ft.lbf) for bolt B
- Connect the generator connector.
- Connect the generator wire with the nut, and install the cap.
Torque: 9.8 N.m (100 kgf.cm, 87 in.lbf)
- Install the wire clamp to the wire clip.
- Install the wire clip on the wire connectors to the generator.
- Install the generator with the 2 bolts.
- INSTALL DRIVE BELT
Hook SST on the hexagonal portion of the drive belt tensioner bracket, compress the drive belt tension by turning the drive belt tensioner bracket clockwise, and install the drive belt.
SST 09249-63010
NOTE: Compress the drive belt tensioner by taking 3 seconds or more and installed the drive belt.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.