2005 Toyota PriusFACTORY OEM SERVICE PROCEDURE

Service Data

SERVICE DATA - EMISSION CONTROL

Air-fuel ratio sensor E5-23 (A1A+) - E5-28 (E1) 3.0 to 3.6 V
Voltage E5-23 (A1A+) - E5-28 (E1) 3.0 to 3.6 V
Voltage E5-22 (A1A-)-E5-28 (E1) 2.7 to 3.3 V
Resistance 1 (HT)-2 (+B) 1.8 to 3.9Ω at 20°C (68°F)
Resistance 2 (+B)-4 (AF-) 10 kΩ or higher
Vapor pressure sensor 1-3 4.5 to 5.5 V
Voltage 1-3 4.5 to 5.5 V
Voltage 2-3 3.0 to 3.6 V
Vacuum switching valve assy No. 2 1-2 26 to 30 Ω at 20°C (68°F)
Resistance 1-2 26 to 30 Ω at 20°C (68°F)
Charcoal canister vacuum switching valve 1-2 36 to 42 Ω at 20°C (68°F)
Resistance 1-2 36 to 42 Ω at 20°C (68°F)
Trap w/ outlet valve canister assy 1 - 2 25 to 30 Ω at 20°C (68°F)
Resistance (VSV for CCV (canister closed valve)) 1 - 2 25 to 30 Ω at 20°C (68°F)
Resistance (VSV for CCV (canister closed valve)) 1 - 2 32 to 40 Ω at 100°C (212°F)
Heated oxygen sensor 1 (HT) - 2 (+B) 11 to 16 Ω at 20°C (68°F)
Resistance 1 (HT) - 2 (+B) 11 to 16 Ω at 20°C (68°F)
Resistance 1 (HT)-4 (E) 10 kΩ or higher
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.