Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2005 Toyota PriusFACTORY OEM SERVICE PROCEDURE
Hand-held tester
- PERFORM ACTIVE TEST BY HAND-HELD TESTER (OPERATE CIRCUIT OPENING RELAY)
- Connect the hand-held tester to the DLC3.
- Turn the power switch ON (IG).
- Turn the hand-held tester ON.
- Select the item: DIAGNOSIS/ENHANCED OBD II/ACTIVE TEST/FUEL PUMP/SPD.
- Check the relay operation while operating it using the hand-held tester.
Standard: Operating noise can be heard from the relay.
- OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (See PROBLEM SYMPTOMS TABLE )
- NG: GO TO NEXT STEP
- INSPECT POWER SOURCE CIRCUIT (See ECM POWER SOURCE CIRCUIT
)
- NG: REPAIR OR REPLACE POWER SOURCE CIRCUIT COMPONENTS
- OK: GO TO NEXT STEP
- INSPECT INTEGRATION RELAY (C/OPN RELAY)
- Remove the integration relay from the engine room R/B.
- Inspect the circuit opening relay.
Standard:
TESTER CONNECTION SPECIFIED CONDITION DESCRIPTIONTester Connection Specified Condition (3G-5) - (3G-8) 10 kΩ or higher (3G-5) - (3G-8) Below 1 Ω (Apply battery voltage to terminals 3G-6 and 3G-7) - Reinstall the integration relay.
- NG: REPLACE INTEGRATION RELAY
- OK: GO TO NEXT STEP
- INSPECT ECM (FC VOLTAGE)
- Turn the power switch ON (IG).
- Measure the voltage between the specified terminals of the E5 and E6 ECM connectors.
Standard:
TESTER CONNECTION SPECIFIED CONDITION DESCRIPTIONTester Connection Specified Condition FC (E6-10) - E1 (E5-28) 9 to 14 V
- OK: Go to step 5
- NG: GO TO NEXT STEP
CHECK AND REPAIR HARNESS OR CONNECTOR
- INSPECT FUEL PUMP
- Disconnect the F14 fuel pump connector.
- Inspect the fuel pump resistance.
- Measure the resistance between terminals 3 and 7.
Standard:
TESTER CONNECTION SPECIFIED CONDITION DESCRIPTIONTester Connection Specified Condition 3 - 7 0.2 to 3.0 Ω at 20°C (68°F) - Inspect the fuel pump operation
- Apply battery voltage to the fuel pump terminals. Check that the pump operates.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.