2005 Toyota PriusFACTORY OEM SERVICE PROCEDURE

Hand-held tester

  1. PERFORM ACTIVE TEST BY HAND-HELD TESTER (OPERATE CIRCUIT OPENING RELAY) 
    1. Connect the hand-held tester to the DLC3.
    2. Turn the power switch ON (IG).
    3. Turn the hand-held tester ON.
    4. Select the item: DIAGNOSIS/ENHANCED OBD II/ACTIVE TEST/FUEL PUMP/SPD.
    5. Check the relay operation while operating it using the hand-held tester.

      Standard: Operating noise can be heard from the relay. 

    1. OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (See  PROBLEM SYMPTOMS TABLE   ) 
    2. NG: GO TO NEXT STEP 
  2. INSPECT POWER SOURCE CIRCUIT (See  ECM POWER SOURCE CIRCUIT   ) 
    1. NG: REPAIR OR REPLACE POWER SOURCE CIRCUIT COMPONENTS 
    2. OK: GO TO NEXT STEP 
  3. INSPECT INTEGRATION RELAY (C/OPN RELAY) 
    1. Remove the integration relay from the engine room R/B.
    2. Inspect the circuit opening relay.

      Standard: 

      TESTER CONNECTION SPECIFIED CONDITION DESCRIPTION

      Tester Connection Specified Condition
      (3G-5) - (3G-8) 10 kΩ or higher
      (3G-5) - (3G-8) Below 1 Ω (Apply battery voltage to terminals 3G-6 and 3G-7)
    3. Reinstall the integration relay.
      Fig 1: Inspecting Integration Relay (C/OPN Relay)
      G02619690Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. NG: REPLACE INTEGRATION RELAY 
    2. OK: GO TO NEXT STEP 
  4. INSPECT ECM (FC VOLTAGE) 
    1. Turn the power switch ON (IG).
    2. Measure the voltage between the specified terminals of the E5 and E6 ECM connectors.

      Standard: 

      TESTER CONNECTION SPECIFIED CONDITION DESCRIPTION

      Tester Connection Specified Condition
      FC (E6-10) - E1 (E5-28) 9 to 14 V
      Fig 2: Identifying E5 And E6 ECM Connectors Terminals
      G02619691Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. OK: Go to step 5 
    2. NG: GO TO NEXT STEP 

      CHECK AND REPAIR HARNESS OR CONNECTOR 

  5. INSPECT FUEL PUMP 
    1. Disconnect the F14 fuel pump connector.
    2. Inspect the fuel pump resistance.
      1. Measure the resistance between terminals 3 and 7.

      Standard: 

      TESTER CONNECTION SPECIFIED CONDITION DESCRIPTION

      Tester Connection Specified Condition
      3 - 7 0.2 to 3.0 Ω at 20°C (68°F)
    3. Inspect the fuel pump operation
      1. Apply battery voltage to the fuel pump terminals. Check that the pump operates.
        Fig 3: Identifying F14 Fuel Pump Connector Terminals
        G02619692Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.