2005 Toyota Matrix Base, 4WDFACTORY OEM SERVICE PROCEDURE

Mode 6 - 2005 TOYOTA: AVALON

TID $07: A/F SENSOR HEATER

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.00017 (A) Maximum heater current (Bank 1) Malfunction criterion for A/F sensor heater
1 $10 Multiply by 0.00017 (A) Maximum heater current (Bank 2) Malfunction criterion for A/F sensor heater
HEATED OXYGEN SENSOR HEATER

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$42 $90 Multiply by 0.001 [A] Maximum sensor heater current Minimum test limit Maximum test limit
THERMOSTAT

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$E1 $E8 Multiply by 0.1 [Β°C] ECT sensor output when estimated ECT reached to malfunction criteria Malfunction criteria Maximum test limit
HO2S BANK 1 SENSOR 2

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$02 $07 Multiply by 0.001 [V] Minimum sensor voltage Minimum test limit Maximum test limit
$02 $08 Multiply by 0.001 [V] Maximum sensor voltage Minimum test limit Maximum test limit
$02 $8F Multiply by 0.001 [g] Maximum oxygen storage capacity 0 Maximum test limit
MISFIRE MONITOR - ALL CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A1 $0B Multiply by 1 [time] Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total 0 65535
$A1 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles-total 0 65535
MISFIRE MONITOR - CYLINDER 1

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A2 $0B Multiply by 1 [time] Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total 0 65535
$A2 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles-total 0 65535
MISFIRE MONITOR - CYLINDER 2

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A3 $0 B Multiply by 1 [time] Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total 0 65535
$A3 $ 0C Multiply by 1 [time] Misfire counts for last and current driving cycles-total 0 65535
MISFIRE MONITOR - CYLINDER 3

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A4 $0B Multiply by 1 [time] Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total 0 65535
$A4 $ 0C Multiply by 1 [time] Misfire counts for last and current driving cycles-total 0 65535
MISFIRE MONITOR - CYLINDER 4

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A5 $0B Multiply by 1 [time] Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total 0 65535
$A5 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles-total 0 65535
MISFIRE MONITOR - CYLINDER 5

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A6 $0B Multiply by 1 [time] Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total 0 65535
$A6 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles-total 0 65535
MISFIRE MONITOR - CYLINDER 6

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A7 $0B Multiply by 1 [time] Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total 0 65535
$A7 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles-total 0 65535
CATALYST BANK 1 - ACTIVE A/F CONTROL METHOD

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$21 $A9 Multiply by 0.0003 [no dimension] Oxygen storage capacity of catalyst Minimum test limit for catalyst Maximum test limit for catalyst
CATALYST BANK 2 - ACTIVE A/F CONTROL METHOD

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$22 $A9 Multiply by 0.0003 [no dimension] Oxygen storage capacity of catalyst Minimum test limit for catalyst Maximum test limit for catalyst
AIR-FUEL RATIO SENSOR CURRENT

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$01 $91 Multiply by 0.003 [mA] Air-fuel ratio sensor current for bank 1 sensor 1 Malfunction criterion for low side rationality Malfunction criterion for high side rationality
AIR-FUEL RATIO SENSOR RESPONSE RATE

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$01 $8E Multiply by 0.0003 [no dimension] Response rate deterioration level for bank 1 sensor 1 Malfunction criterion for response rate deterioration Maximum test limit
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.