2005 Toyota MR2 C65MFACTORY OEM SERVICE PROCEDURE

Inspection Procedure

HINT:

  • Even though terminal TC is not connected with terminal CG, the MIL blinks.
  • For the above phenomenon, an open or short in the wire harness, or malfunction inside the ECM is the likely cause.
  1. Check voltage between terminals TC and CG of DLC3. 

    PREPARATION: 

    Turn the ignition switch to ON.

    CHECK: 

    Measure the voltage between terminals TC and CG of the DLC3.

    OK: Voltage: 9 to 14 V 

    Fig 1: Checking Voltage Between TC And CG
    G02653054Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. Check continuity between terminal CG of DLC3 and body ground. 
    • NG: Repair or replace harness or connector. 
    • OK: Go to next step. 
  3. Check for open and short circuit in harness and connectors between ECM and DLC3, and DLC3 and body ground (See  HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE  ). 