SFI System (5VZ-FE): Injector: Inspection
- INSPECT INJECTOR RESISTANCE
Using an ohmmeter, measure the resistance between the terminals.
Resistance: Approx. 13.8 Ω at 20 °C (68 °F)
If the resistance is not as specified, replace the injector.
- INSPECT INJECTOR INJECTION CAUTION: Keep injector clear of sparks during the test.
- Disconnect the fuel inlet pipe from the fuel tube.
- Connect SST (attachment and hose) to the fuel tube.
SST 09268-41047 (09268-52011)
- Connect the fuel return hose, SST (union) and SST (hose) to the fuel pressure regulator.
SST 09268-41047 (09268-41091)
- Connect SST (hose) to the injector.
SST 09268-41047
- Put the injector into the graduated cylinder.
HINT:
Install a suitable vinyl hose onto the injector to prevent gasoline from splashing out.
- Connect a TOYOTA hand-held tester to the DLC3.
- Connect SST (wire) to the injector and battery for 15 seconds, and measure the injection volume with a graduated cylinder. Test each injector 2 or 3 times.
SST 09842-30070
Volume: 56 - 69 cm 3 (3.4 - 4.2 cu in.) per 15 sec.
Difference between each injector:
1.3 cm 3 (0.08 cu in.) or less
If the injection volume is not as specified, replace the injector.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- INSPECT LEAKAGE
- In the condition above, disconnect the tester probes of SST (wire) from the battery and check the fuel leakage from the injector.
SST 09842-30070
Fuel drop: 1 drop or less per 12 minutes
- Turn the ignition switch OFF.
- Disconnect the negative (-) terminal cable from the battery.
- Remove the SST.
SST 09268-41047, 09842-30070
- Disconnect the TOYOTA hand-held tester from the DLC3.
- In the condition above, disconnect the tester probes of SST (wire) from the battery and check the fuel leakage from the injector.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.