2004 Toyota Matrix Base, 4WDFACTORY OEM SERVICE PROCEDURE
Inspection Procedure
- INSPECT ECM (+B VOLTAGE)
- Turn the ignition switch ON.
- Measure the voltage between the terminals of the E4 and E6 ECM connectors.
Standard:
CONNECTOR SPECIFIED CONDITIONTester Connection Specified Condition +B (E6-1) - E1 (E4-7) 8 to 14 V
- OK: REPLACE ECM (See REPLACEMENT )
- NG: Go to next step.
- CHECK HARNESS AND CONNECTOR(ECM - BODY GROUND)
- Disconnect the E4 ECM connector.
- Check the resistance between the wire harness side connectors.
Standard (Check for open):
CONNECTOR SPECIFIED CONDITIONTester Connection Specified Condition E1 (E4-7) - Body ground Below 1 Ω - Reconnect the ECM connector.
- NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
- OK: Go to next step.
- INSPECT IGNITION OR STARTER SWITCH ASSY
- Disconnect the I11 ignition switch connector.
- Check for continuity between the connector terminals shown in the chart below.CONNECTOR CONTINUITY
Switch Position Tester Connection Specified Condition LOCK All Terminals No continuity ACC 1-3 Continuity ON 1-2, 1-3, 2-3, 5-6 Continuity START 1-2, 4-5, 4-6, 5-6 Continuity - Reconnect the ignition switch connector.
- NG: REPLACE IGNITION OR STARTER SWITCH ASSY
- OK: Go to next step.
- CHECK FUSE (EFI FUSE)
- Remove the EFI fuse from the engine room R/B.
- Check for continuity in the EFI fuse.
Standard: Continuity
- Reinstall the EFI fuse.
- NG: CHECK FOR SHORT IN ALL HARNESSES AND COMPONENTS CONNECTED FUSE
- OK: Go to next step.
- INSPECT EFI RELAY
- Remove the EFI relay from the engine room R/B.
- Check for continuity in the circuit EFI relay.
Standard:
- Reinstall the EFI fuse.
- NG: REPLACE EFI RELAY
- OK: Go to next step.
- CHECK HARNESS AND CONNECTOR (EFI RELAY - ECM, EFI RELAY - BODY GROUND)
- Check the harness and connector between the EFI relay and ECM.
- Remove the EFI relay from the engine room R/B.
- Disconnect the E6 ECM connector.
- Check the resistance between the wire harness side connectors.
Standard (Check for open):
CONNECTOR (OPEN) SPECIFIED CONDITIONTester Connection Specified Condition EFI relay (3) - +B (E6-1) Below 1 Ω Standard (Check for short):
CONNECTOR (SHORT) SPECIFIED CONDITIONTester Connection Specified Condition EFI relay (3) or +B (E6-1) - Body ground 10 kΩ or higher - Reconnect the ECM connector.
- Reinstall the EFI relay.
- Check the harness and connector between the EFI relay and body ground.
- OK: REPAIR OR REPLACE HARNESS OR CONNECTOR
- NG: CHECK AND REPAIR HARNESS AND CONNECTOR (TERMINAL +B OF ECM - BATTERY POSITIVE TERMINAL)
- Check the harness and connector between the EFI relay and ECM.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.