1997 Toyota Previa LE, AWDFACTORY OEM SERVICE PROCEDURE

EGR Check Valve

  1. Remove EGR check valve. See Figure. Apply air pressure on Orange-colored side of EGR check valve. Air should flow through EGR check valve.
  2. Apply air pressure on Black-colored side of EGR check valve. Air should not flow through EGR check valve. Replace EGR check valve if defective.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.