1996 Toyota Previa LE, AWDFACTORY OEM SERVICE PROCEDURE

A/C Idle-Up Valve

NOTE: The A/C idle-up valve may also be referred to as A/C idle-up Vacuum Switching Valve (VSV).
  1. Remove A/C idle-up valve. The A/C idle-up valve is located on side of air cleaner case, near the air intake, and contains a Black 2-pin electrical connector. Two hoses are connected to A/C idle-up valve.
    NOTE: The A/C idle-up valve may also be identified using appropriate illustration in THEORY/OPERATION article and wire color. See appropriate wiring diagram in WIRING DIAGRAMS article.
  2. Using ohmmeter, ensure continuity exists between electrical terminals on A/C idle-up valve and resistance is 30-34 ohms at 68Β°F (20Β°C). Replace A/C idle-up valve if no continuity exists or resistance is not within specification.
  3. Ensure no continuity exists between each electrical terminal and the body of A/C idle-up valve. Replace A/C idle-up valve if continuity exists between electrical terminal and body of A/C idle-up valve.
  4. To test A/C idle-up valve operation, apply air pressure to designated area with battery disconnected and ensure no air passes through the A/C idle-up valve. See Fig 1.
  5. Apply battery voltage and ground to electrical terminals on A/C idle-up valve. Apply air pressure to designated area with battery connected and ensure air passes through the A/C idle-up valve. See Fig 1. Replace A/C idle-up valve if defective.
Fig 1: Testing Typical A/C Idle-Up Valve
G93H80124Courtesy of Β© TOYOTA, LICENSE AGREEMENT TMS1002
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.