1994 Toyota Corolla Base, AutomaticFACTORY OEM SERVICE PROCEDURE

DTC 14 - Ignition Signal

ECM determines ignition timing. ECM turns on "Tr1" circuit at predetermined angle before desired ignition timing, and outputs an ignition signal to ignitor. Since the width of the "IGT" is constant, dwell angle control circuit in ignitor determines the time control circuit starts primary current flow to ignition coil, based on engine RPM and ignition timing one revolution ago, that is, the time "Tr2" circuit turns on.

When it reaches the ignition timing, ECM turns off "Tr1" and outputs the "IGT" signal "0". This turns off "Tr2", interrupting the primary current flow and generating a high voltage in the secondary coil, firing the spark plugs. Also, by the counter electromotive force generated when the primary current is interrupted, the ignitor sends an ignition confirmation signal (IGF) to the ECM. The ECM stops fuel injection as a fail safe function when "IGF" signal is not input to ECM.

If "IGF" signal to ECM is not present after 4 consecutive "IGT" signals, check for open or short in "IGF" or "IGT" circuit from ignitor to ECM. Check for faulty ignitor or ECM.

Fig 1: DTC 14 - Schematic
G94E45140Courtesy of Β© TOYOTA, LICENSE AGREEMENT TMS1002
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.