1992 Toyota Land CruiserFACTORY OEM SERVICE PROCEDURE

Airflow Meter

AIRFLOW METER RESISTANCE

Application & Terminals (1) Ohms
E2 & VC 200-400
E2 & THA
-4°F (20°C) 10,000-20,000
32°F (0°C) 4000-7000
68°F (20°C) 2000-3000
104°F (40°C) 900-1300
140°F (60°C) 400-700
E1 & FC
Measuring Plate Fully Closed Infinite
Measuring Plate Other Than Closed 0
E2 & VS
Measuring Plate Fully Closed 200-600
Measuring Plate Fully Opened 20-1200
(1) For terminal identification and testing, see I - SYS/COMP TESTS article in the ENGINE PERFORMANCE Section.