1983 Toyota Starlet K40FACTORY OEM SERVICE PROCEDURE

Air Temperature Sensor

  1. With ignition "OFF", unplug electrical connector at air flow meter. Connect an ohmmeter between terminals E2 and "THA". Measure and record air temperature.
  2. Ohmmeter readings should be as specified. See Temperature/Resistance Relationship charts. If not, check insulation resistance with ohmmeter between terminal "THA" or terminal and ground. Use air flow meter as ground.
  3. Infinity ohmmeter reading should be obtained. If values are not as specified, replace electrical harness or air flow meter assembly, as required.
TEMPERATURE/RESISTANCE RELATIONSHIP

Temperature Β°F(Β°C) Ohms
32 (0) 4000-7000
68 (20) 2000-3000
104 (40) 9000-13,000
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.