2012 Suzuki SX4 BaseFACTORY OEM SERVICE PROCEDURE

Generator Disassembly and Reassembly: Reassembly

Reference: GENERATOR DISASSEMBLY AND REASSEMBLY 

Reverse disassembly procedure for reassembly noting the following.

  • Tighten each bolt, nut, screw and pulley (CVT model) to specified torque referring to GENERATOR COMPONENTS .
  • Be sure to install brushes (1) in the proper direction as shown in figure and solder brush wires (2) and stator leads (3).
  • Fig 1: Installing Brushes
    G06867288Courtesy of SUZUKI OF AMERICA CORP.
  • Install drive end bearing to drive end frame (1) using special tool and hydraulic press (2).

    Special Tool 

    (A): 09913-76010 

    Fig 2: Installing Drive End Bearing To Drive End Frame Using Special Tool And Hydraulic Press
    G06867289Courtesy of SUZUKI OF AMERICA CORP.
  • Push brushes into brush holder, then support brushes by inserting appropriate wire (1) before installing IC regulator assembly (2) to rear end frame (3).
    NOTE: After installing rotor, remove wire.