Air Conditioning System DTCS
AIR CONDITIONING SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) LIST
| DTC | Detection item | Condition when trouble detected (DTC is determined when following condition detected) |
|---|---|---|
| B1502 | Inside Air Temperature Sensor Circuit Malfunction | Signal voltage of inside air temperature sensor is higher than specification. |
| Signal voltage of inside air temperature sensor is lower than specification. | ||
| B1503 | Evaporator Temperature Sensor Circuit Malfunction | Signal voltage of evaporator temperature sensor is higher than specification. |
| Signal voltage of evaporator temperature sensor is lower than specification. | ||
| B1504 | Sun load Sensor Circuit Malfunction |
|
| Signal voltage of sun load sensor is lower than specification. | ||
| B1511 | Temperature Control Actuator (Position Sensor) and/or Its Circuit Malfunction | Signal voltage of position sensor included in temperature control actuator is higher than specification. |
| Signal voltage of position sensor included in temperature control actuator is lower than specification. | ||
| B1512 | Air Flow Control Actuator (Position Sensor) and/or Its Circuit Malfunction | Signal voltage of position sensor included in airflow control actuator is higher than specification. |
| Signal voltage of position sensor included in airflow control actuator is lower than specification. | ||
| B1513 | Temperature Control Actuator (Motor) and/or Its Circuit Malfunction | Motor of temperature control actuator is not operated more than specified time. |
| B1514 | Air Flow Control Actuator (Motor) and/or Its Circuit Malfunction | Motor of air flow control actuator is not operated more than specified time. |
| B1520 | Temperature Selector Malfunction | Signal voltage of temperature selector in HVAC control module is higher than specification. |
| Signal voltage of temperature selector in HVAC control module is lower than specification. | ||
| B1521 | Blower Speed Selector Malfunction | Signal voltage of blower speed selector in HVAC control module is higher than specification. |
| Signal voltage of blower speed selector in HVAC control module is lower than specification. | ||
| B1522 | Air Flow Selector Malfunction | Signal voltage of airflow selector in HVAC control module is higher than specification. |
| Signal voltage of airflow selector in HVAC control module is lower than specification. | ||
| B1541 | Back-up Power Supply Circuit Malfunction |
|
| B1546 | A/C Refrigerant Pressure Malfunction |
|
| B1551 | Serial Communication Circuit Malfunction | Circuit voltage of serial communication circuit is higher than specification. |
| Circuit voltage of serial communication circuit is lower than specification. | ||
| B1552 | HVAC Control Module Check Sum Error | HVAC control module received unspecified data from BCM more than 8 times. |
| B1553 | CAN Communication Circuit Malfunction | HVAC control module received signal indicating reception error from ECM. |
| B1557 | VSS Signal Failure | HVAC control module receives invalid data of VSS signal from BCM. |
| B1561 | ECT signal Failure | HVAC control module receives invalid data of ECT signal from BCM. |
| B1562 | Outside Temperature Sensor Signal Failure | HVAC control module receives invalid data of outside air temperature sensor signal from BCM. |
| B1563 | A/C Refrigerant Pressure Sensor Signal Failure | HVAC control module receives invalid data of A/C refrigerant pressure sensor signal from BCM. |
| B1570 | Engine Type Signal Failure | HVAC control module receives invalid data of engine type signal from BCM. |
| B1571 | Combination Meter Spec Signal Failure | HVAC control module receives invalid data of combination meter Spec signal from BCM. |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.