2007 Suzuki SX4 Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Generator Inspection: Stator

  • Using ohmmeter, check all leads for continuity. If there is no continuity, replace stator (1).
    Fig 1: Checking Continuity Between Stator Coil Leads
    G04847120Courtesy of SUZUKI OF AMERICA CORP.
  • Using ohmmeter, check that there is no continuity between coil leads (2) and stator core (1). If there is continuity, replace stator.
    Fig 2: Checking Continuity Between Coil Leads And Stator Core
    G04847121Courtesy of SUZUKI OF AMERICA CORP.