2007 Suzuki Aerio Base, AWDFACTORY OEM SERVICE PROCEDURE

Generator Inspection: Rectifier

  1. Using an ohmmeter, connect one tester probe to the "B" terminal (1) and the other to each rectifier terminal (2).
    Fig 1: Connecting One Tester Probe To B Terminal
    G04590082Courtesy of SUZUKI OF AMERICA CORP.
  2. Reverse the polarity of the tester probes and repeat step Β 1).
  3. Check that one shows continuity and the other shows no continuity.

    If there is continuity, replace the rectifier.

  4. Using an ohmmeter, connect one tester probe to each negative terminal (1) and the other to each rectifier terminal (2).
    Fig 2: Connecting One Tester Probe To Negative Terminal And Other To Rectifier Terminal
    G04590083Courtesy of SUZUKI OF AMERICA CORP.
  5. Reverse the polarity of the tester probes and repeat step Β 4).
  6. Check that one shows continuity and the other shows no continuity.

    If there is continuity, replace the rectifier.