Secondary Parameters And Enable Conditions

Additional specific conditions for "mechanical stop not reached (activated position = STOP_ON diagnose):

  • IGK "ON"
  • No VIM sensor electrical error
  • No VIM actuator electrical error
  • Ambient temperature > -9.75 °C
  • Time after exit start to after start > 1 s
  • 10.968 V < battery voltage < 16.046 V
  • Low pressure available in the intake manifold and this for a sufficient time (to insure sufficient vacuum in the vacuum reservoir)
  • The flap had sufficient time to reached the set point value
  • No VIM "mechanical stop not reached (deactivated position = STOP_OFF) error
  • Intake air temperature > 0 °C
  • Number of VIM activations since engine start >= 1
  • VIM activated position requested

Additional specific conditions for "mechanical stop not reached (deactivated position = STOP_OFF diagnose):

  • IGK "ON"
  • No VIM sensor electrical error
  • No VIM actuator electrical error
  • Ambient temperature > -9.75 °C
  • Time after exit start to after start > 1 s
  • 10.968 V < Battery voltage < 16.046 V
  • Low pressure available in the intake manifold and this for a sufficient time (to insure sufficient vacuum in the vacuum reservoir)
  • The flap had sufficient time to reached the set point value
  • No VIM "mechanical stop not reached (activated position = STOP_ON) error
  • Intake air temperature > 0 °C
  • VIM deactivated position requested
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.