2000 Suzuki Swift GA, AutomaticFACTORY OEM SERVICE PROCEDURE

Generator Output: Swift

  1. Check generator wiring harness electrical connections at generator. Check drive belt tension. See BELT TENSIONΒ  under ADJUSTMENTS. Ensure battery is fully charged.
  2. Connect voltmeter between ground and generator "B" (battery) terminal. Connect ammeter positive lead to generator "B" (battery) terminal. Connect ammeter negative lead to positive battery terminal on the battery. See Figure .
  3. To check generator no-load output, ensure all accessories are off. Start and idle engine. Increase engine speed to 2000 RPM and note output voltage and output amperage. Output voltage and output amperage should be within specification. See GENERATOR OUTPUT SPECIFICATIONSΒ  table.
    NOTE: Output voltage may vary slightly depending on temperature of IC voltage regulator case.
  4. If output voltage and output amperage are within specification, go to next step. If output voltage is less than specified, go to step Β 6 . If output voltage exceeds specification, check ground on brushes. If ground on brushes is okay, replace IC voltage regulator. See OVERHAULΒ  .
  5. To check generator high-load output, allow engine to idle. Increase engine speed to 2000 RPM. Turn on headlights and heater motor. Note output amperage. Output amperage should be at least 20 amps. If output amperage is less than 20 amps, go to next step.
  6. Repair or replace generator as necessary. If repairing generator, see BENCH TESTINGΒ  .
GENERATOR OUTPUT SPECIFICATIONS

Application Specification
Esteem & Swift
Output Amperage
At No-Load 10 Amps Maximum
At High-Load 20 Amps Minimum
Output Voltage (1) 14.4-15.0 Volts
Grand Vitara & Vitara (85-Amp Generator)
Output Amperage
At No-Load 10 Amps Maximum
At High-Load 30 Amps Minimum
Output Voltage (1) 14.1-15.2 Volts
Vitara (60- & 70-Amp Generator)
Output Amperage
At No-Load 10 Amps Maximum
At High-Load (2)
Output Voltage (1) 14.4-15.0 Volts
(1) Output voltage specification listed is at 68Β°F (20Β°C). Output voltage may vary slightly depending on temperature of IC voltage regulator case.
(2) On 60-amp generator, minimum output specification is 42 amps. On 70-amp generator, minimum output specification is 49 amps.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.