2025 Subaru Outback BaseFACTORY OEM SERVICE PROCEDURE

Check The Intake Air Temperature Sensor Unit

Raise the temperature gradually, measure the resistance between the air flow and intake air temperature sensor terminals when the temperature is 20°C (68°F) and 60°C (140°F).

G00686980Courtesy of SUBARU OF AMERICA, INC.
(A) Drier
(B) Intake air temperature sensor unit
(C) Thermometer
Temperature Terminal No. Standard
20°C (68°F) 2 and 4 2.21 - 2.69 kΩ
60°C (140°F) 0.493 - 0.667 kΩ