2022 Subaru Legacy BaseFACTORY OEM SERVICE PROCEDURE

Check Relay

  1. Measure the resistance between relay terminals.
    Terminal No. Inspection conditions Standard Circuit
    3 - 1 Always 1 MΞ© or more
    G13621302Courtesy of SUBARU OF AMERICA, INC.
    3 - 5 Always Less than 1 Ξ©
    3 - 1 Apply battery voltage between terminals 4 and 2. Less than 1 Ξ©
  2. Replace the relay if the inspection result is not within the standard value.