2021 Subaru Forester BaseFACTORY OEM SERVICE PROCEDURE

Quick Charging

Charge the battery in a short period of time with a relatively large current by using a quick charger. Charge the battery with the current value at approximately 1/2 of battery's rating capacity. (See the table below.)

CAUTION:
  • Quick charging is accompanied by a large amount of heat generation. Charging should be completed in up to 30 minutes regardless of battery size.
  • Quick charging is used to recover the battery until it can start the vehicle. For full charging, use the normal charging method.
  • Keep the electrolyte temperature at 55Β°C (131Β°F) or less while quick charging. Stop charging when the temperature exceeds this value.
Type Charging current (A) CCA (A)
Q-85 27.5 - 32.5 620
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.