Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2020 Subaru Outback BaseFACTORY OEM SERVICE PROCEDURE
Electrical Specification
- OUTER MIRROR Control Module
Terminal No. Contents Measuring condition Standard Note Door mirror (driver's seat) Door mirror (passenger's seat) (Df21) or (Df23) No. 1 ↔ Chassis ground Memory sensor power supply Memory sensor power supply Always 5.0 V - (Df21) or (Df23) No. 2 ↔ Chassis ground Memory sensor input (horizontal) Memory sensor input (horizontal) Always 0 - 5.0 V - (Df21) or (Df23) No. 3 ↔ Chassis ground Memory sensor input (vertical) Memory sensor input (vertical) Always 0 - 5.0 V - (Df21) or (Df23) No. 4 ↔ Chassis ground SET SW input - Switch ON 1.6 V or less - Switch OFF 10 kΩ or more - (Df21) or (Df23) No. 5 ↔ Chassis ground Memory 1 SW input - Switch ON 1.6 V or less - Switch OFF 10 kΩ or more - (Df21) or (Df23) No. 6 ↔ Chassis ground Memory 2 SW input - Switch ON 1.6 V or less - Switch OFF 10 kΩ or more - (Df21) or (Df23) No. 7 ↔ Chassis ground GND GND Always 1 Ω or less - (Df21) or (Df23) No. 8 ↔ Chassis ground Remote control mirror SW MCL input (L side) - When the mirror surface is operated (up) 3.7 V or more Common to both the right and left mirror operation When the mirror surface is operated (down) 1.6 V or less Common to both the right and left mirror operation When the mirror surface is operated (right) 3.7 V or more Common to both the right and left mirror operation When the mirror surface is operated (left) 1.6 V or less Common to both the right and left mirror operation (Df21) or (Df23) No. 9 ↔ Chassis ground Remote control mirror SW MAR input (R side) - When the mirror surface is operated (up) 10 kΩ or more Only when the right mirror is operated When the mirror surface is operated (down) 10 kΩ or more Only when the right mirror is operated When the mirror surface is operated (right) 1.6 V or less Only when the right mirror is operated When the mirror surface is operated (left) 3.7 V or more Only when the right mirror is operated (Df21) or (Df23) No. 10 ↔ Chassis ground Remote control mirror SW MBR input (R side) - When the mirror surface is operated (up) 1.6 V or less Only when the right mirror is operated When the mirror surface is operated (down) 3.7 V or more Only when the right mirror is operated When the mirror surface is operated (right) 10 kΩ or more Only when the right mirror is operated When the mirror surface is operated (left) 10 kΩ or more Only when the right mirror is operated (Df21) or (Df23) No. 11 ↔ Chassis ground Remote control mirror SW MAL input (L side) - When the mirror surface is operated (up) 10 kΩ or more Only when the left mirror is operated When the mirror surface is operated (down) 10 kΩ or more Only when the left mirror is operated When the mirror surface is operated (right) 1.6 V or less Only when the left mirror is operated When the mirror surface is operated (left) 3.7 V or more Only when the left mirror is operated (Df21) or (Df23) No. 12 ↔ Chassis ground Remote control mirror SW MBL input (L side) - When the mirror surface is operated (up) 1.6 V or less Only when the left mirror is operated When the mirror surface is operated (down) 3.7 V or more Only when the left mirror is operated When the mirror surface is operated (right) 10 kΩ or more Only when the left mirror is operated When the mirror surface is operated (left) 10 kΩ or more Only when the left mirror is operated (Df21) or (Df23) No. 13 ↔ Chassis ground Memory sensor GND Memory sensor GND Always 1 Ω or less - (Df21) or (Df23) No. 14 ↔ Chassis ground ECM power supply ECM power supply Always 9.0 - 16 V - (Df22) or (Df24) No. 1 ↔ Chassis ground Electric retraction SW input (OPR) - During the extension operation by the electric retraction system 3.3 V or more - During the retracting operation by the electric retraction system 10 kΩ or more - (Df22) or (Df24) No. 2 ↔ Chassis ground Remote control mirror SW power supply - When the electric retraction system and mirror surface are operated 9.0 - 16 V - (Df22) or (Df24) No. 3 CAN communication Hi CAN communication Hi - Cannot be measured - (Df22) or (Df24) No. 4 CAN communication Low CAN communication Low - Cannot be measured - (Df22) or (Df24) No. 5 ↔ Chassis ground Output for courtesy light Output for courtesy light When door is open (+B voltage) -0.8 V or more - (Df22) or (Df24) No. 6 ↔ Chassis ground Mirror surface motor output (vertical) Mirror surface motor output (vertical) When the mirror surface is operated (up) 1.0 V or less - When the mirror surface is operated (down) (+B voltage) -0.6 V or more - When the mirror surface is operated (right) 10 kΩ or more - When the mirror surface is operated (left) 10 kΩ or more - (Df22) or (Df24) No. 7 ↔ Chassis ground Mirror surface motor output (horizontal) Mirror surface motor output (horizontal) When the mirror surface is operated (up) 10 kΩ or more - When the mirror surface is operated (down) 10 kΩ or more - When the mirror surface is operated (right) 1.0 V or less - When the mirror surface is operated (left) (+B voltage) -0.6 V or more - (Df22) or (Df24) No. 8 ↔ Chassis ground Mirror surface motor output (common) Mirror surface motor output (common) When the mirror surface is operated (up) (+B voltage) -0.6 V or more - When the mirror surface is operated (down) 1.0 V or less - When the mirror surface is operated (right) (+B voltage) -0.6 V or more - When the mirror surface is operated (left) 1.0 V or less - (Df22) or (Df24) No. 9 ↔ Chassis ground Remote control mirror SW GND - Always 10 kΩ or more - (Df22) or (Df24) No. 10 ↔ Chassis ground Electric retraction SW input (CLR) - During the extension operation by the electric retraction system 10 kΩ or more - During the retracting operation by the electric retraction system 3.3 V or more - (Df22) or (Df24) No. 11 ↔ Chassis ground IGN SW input IGN SW input IG ON 9.0 - 16 V - (Df22) or (Df24) No. 12 ↔ Chassis ground ACC SW input ACC SW input ACC ON 9.0 - 16 V - (Df22) or (Df24) No. 13 ↔ Chassis ground Electric retraction SW illumination output - Night illumination ON (+B voltage) -0.3 V or more - (Df22) or (Df24) No. 14 ↔ Chassis ground Heater output Heater output Defogger ON (+B voltage) -0.8 V or more - (Df22) or (Df24) No. 15 ↔ Chassis ground Electric retraction motor output Electric retraction motor output (-) During the extension operation by the electric retraction system (+B voltage) -1.1 V or more - During the retracting operation by the electric retraction system 0.9 V or less - (Df22) or (Df24) No. 16 ↔ Chassis ground Electric retraction motor output (+) Electric retraction motor output (+) During the extension operation by the electric retraction system 0.9 V or less - During the retracting operation by the electric retraction system (+B voltage) -1.1 V or more -
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.