2019 Subaru Crosstrek Base, Automatic CVT TransFACTORY OEM SERVICE PROCEDURE

Remote Control Mirror Switch: Inspection

  1. Check the resistance between switch - door mirror terminals.

    Preparation tool: 

    Circuit tester

    G12398790Courtesy of SUBARU OF AMERICA, INC.
    • Changeover switch RH
      Terminal No. Inspection conditions Standard
      12 - 1
      12 - 18
      OFF 1 MΩ or more
      12 - 18
      17 - 1
      UP Less than 1 Ω
      12 - 17
      18 - 1
      DOWN Less than 1 Ω
      12 - 16
      18 - 1
      LEFT Less than 1 Ω
      12 - 18
      16 - 1
      RIGHT Less than 1 Ω
    • Changeover switch LH
    Terminal No. Inspection conditions Standard
    12 - 1
    12 - 21
    OFF 1 MΩ or more
    12 - 20
    21 - 1
    DOWN Less than 1 Ω
    12 - 21
    20 - 1
    UP Less than 1 Ω
    12 - 19
    21 - 1
    LEFT Less than 1 Ω
    12 - 21
    19 - 1
    RIGHT Less than 1 Ω
  2. If the inspection result is not within the standard, replace the switch - door mirror.