2018 Subaru BRZ Limited, Automatic TransFACTORY OEM SERVICE PROCEDURE

Unit Inspection

  1. ST relay check
    1. Check the resistance between relay connector terminals.
    G12587343Courtesy of SUBARU OF AMERICA, INC.
    STANDARD VALUE RESISTANCE SPECIFICATION

    Inspection terminals Inspection conditions Standard value
    1 - 2 20°C 93.8 to 136.4Ω
    3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more
    When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω
    G12587344Courtesy of SUBARU OF AMERICA, INC.
  2. INHIBITOR relay check
    1. Check the resistance between relay connector terminals.
    STANDARD VALUE RESISTANCE SPECIFICATION

    Inspection terminals Inspection conditions Standard value
    1 - 2 20°C 93.8 to 136.4Ω
    3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more
    When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω
    G12587345Courtesy of SUBARU OF AMERICA, INC.
  3. ST CUT relay check (with smart key system)
    1. Check the resistance between relay connector terminals.
    STANDARD VALUE RESISTANCE SPECIFICATION

    Inspection terminals Inspection conditions Standard value
    1 - 2 20°C 93.8 to 136.4Ω
    3 - 4 When the battery voltage is not applied to the terminal 1 and terminal 2: Less than 1 Ω
    When the battery voltage is applied to the terminal 1 and terminal 2: 10 k Ωor more
    3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more
    When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω
    G12587346Courtesy of SUBARU OF AMERICA, INC.
  4. IGS relay check (with smart key system)
    1. Check the resistance between relay connector terminals.
    STANDARD VALUE RESISTANCE SPECIFICATION

    Inspection terminals Inspection conditions Standard value
    1 - 2 20°C 93.8 to 136.4Ω
    3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more
    When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.