2018 Subaru BRZ Limited, Automatic TransFACTORY OEM SERVICE PROCEDURE
Unit Inspection
- ST relay check
- Check the resistance between relay connector terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 1 - 2 20°C 93.8 to 136.4Ω 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω - INHIBITOR relay check
- Check the resistance between relay connector terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 1 - 2 20°C 93.8 to 136.4Ω 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω - ST CUT relay check (with smart key system)
- Check the resistance between relay connector terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 1 - 2 20°C 93.8 to 136.4Ω 3 - 4 When the battery voltage is not applied to the terminal 1 and terminal 2: Less than 1 Ω When the battery voltage is applied to the terminal 1 and terminal 2: 10 k Ωor more 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω - IGS relay check (with smart key system)
- Check the resistance between relay connector terminals.
STANDARD VALUE RESISTANCE SPECIFICATIONInspection terminals Inspection conditions Standard value 1 - 2 20°C 93.8 to 136.4Ω 3 - 5 When the battery voltage is not applied to the terminal 1 and terminal 2: 10 k Ωor more When the battery voltage is applied to the terminal 1 and terminal 2: Less than 1 Ω
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.