2016 Subaru WRX BaseFACTORY OEM SERVICE PROCEDURE

WASTEGATE Control Solenoid Valve

  1. Check that the wastegate control solenoid valve has no deformation, cracks or other damages.
  2. Check the resistance between the wastegate control solenoid valve terminals.
    Fig 1: Checking Resistance Between Wastegate Control Solenoid Valve Terminals
    G07664927Courtesy of SUBARU OF AMERICA, INC.
    Terminal No. Standard
    1 and 2 24±3 Ω (when 20°C (68°F))
  3. Check that air does not come out from (B) when air is blown into (A).
    Fig 2: Checking Air Blowing System
    G09479770Courtesy of SUBARU OF AMERICA, INC.
  4. Connect the battery positive terminal to the terminal No. 1 and the battery negative terminal to the terminal No. 2. Check that air is discharged from (B), when supplying air to (A).
    Fig 3: Connecting Battery Positive Terminal To Terminal No. 1 And Battery Negative Terminal To Terminal No. 2
    G09479771Courtesy of SUBARU OF AMERICA, INC.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.