2016 Subaru WRX BaseFACTORY OEM SERVICE PROCEDURE
Starting System & Charging System (WRX): General Description: Specification
| Item | Specifications | |||
|---|---|---|---|---|
| Vehicle model | CVT | MT | ||
| Starter | Type | Reduction type | ||
| Model | M000T38571 | M000T33176 | ||
| Manufacturer | Mitsubishi Electric | |||
| Voltage and output | 12 V - 1.2 kW | 12 V - 1.0 kW | ||
| Direction of rotation | Counterclockwise (when observed from pinion) | |||
| Number of pinion teeth | 9 | 8 | ||
| No-load characteristics | Voltage | 11 V | ||
| Current | 90 A or less | 95 A or less | ||
| Rotating speed | 2, 370 r/min or more | 2, 500 r/min or more | ||
| Load characteristics | Voltage | 7.5 V | 7.5 V | |
| Current | 300 A | 300 A | ||
| Torque | 10.65 N.m (1.1 kgf-m, 7.8 ft-lb) or more | 8.84 N.m (0.9 kgf-m, 6.5 ft-lb) or more | ||
| Rotating speed | 840 r/min or more | 870 r/min or more | ||
| Lock characteristics | Voltage | 4 V | 4 V | |
| Current | 780 A or less | 680 A or less | ||
| Torque | 20 N.m (2.0 kgf-m, 14.8 ft-lb) or more | 17 N.m (1.7 kgf-m, 12.5 ft-lb) or more | ||
| Generator | Type | Rotating-field three-phase type, voltage regulator built-in type, with load response control system | ||
| Model | A2TX5081 | |||
| Manufacturer | Mitsubishi Electric | |||
| Voltage and output | 12 V - 130 A | |||
| Polarity on ground side | Negative | |||
| Direction of rotation | Clockwise (when observed from pulley side) | |||
| Stator connection | 3-phase Ξ type | |||
| Output current | 1, 500 r/min - 50 A or more 2, 500 r/min - 111 A or more 5, 000 r/min - 133 A or more |
|||
| Regulated voltage | 14.1 - 14.8 V [20Β°C (68Β°F)] | |||
| Rotor slip ring outer diameter | Standard | 22.7 mm (0.894 in) | ||
| Limit | 22.1 mm (0.870 in) | |||
| Brush length | Standard | 22.5 mm (0.886 in) | ||
| Limit | 5.0 mm (0.197 in) | |||
| Battery | Type and capacity | 12 V - 48 AH (55D 23L) | ||
| CCA | 390A | |||
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.