2016 Subaru WRX BaseFACTORY OEM SERVICE PROCEDURE

Starting System & Charging System (WRX): General Description: Specification

Item Specifications
Vehicle model CVT MT
Starter Type Reduction type
Model M000T38571 M000T33176
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 1.2 kW 12 V - 1.0 kW
Direction of rotation Counterclockwise (when observed from pinion)
Number of pinion teeth 9 8
No-load characteristics Voltage 11 V
Current 90 A or less 95 A or less
Rotating speed 2, 370 r/min or more 2, 500 r/min or more
Load characteristics Voltage 7.5 V 7.5 V
Current 300 A 300 A
Torque 10.65 N.m (1.1 kgf-m, 7.8 ft-lb) or more 8.84 N.m (0.9 kgf-m, 6.5 ft-lb) or more
Rotating speed 840 r/min or more 870 r/min or more
Lock characteristics Voltage 4 V 4 V
Current 780 A or less 680 A or less
Torque 20 N.m (2.0 kgf-m, 14.8 ft-lb) or more 17 N.m (1.7 kgf-m, 12.5 ft-lb) or more
Generator Type Rotating-field three-phase type, voltage regulator built-in type, with load response control system
Model A2TX5081
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 130 A
Polarity on ground side Negative
Direction of rotation Clockwise (when observed from pulley side)
Stator connection 3-phase Ξ” type
Output current 1, 500 r/min - 50 A or more
2, 500 r/min - 111 A or more
5, 000 r/min - 133 A or more
Regulated voltage 14.1 - 14.8 V [20Β°C (68Β°F)]
Rotor slip ring outer diameter Standard 22.7 mm (0.894 in)
Limit 22.1 mm (0.870 in)
Brush length Standard 22.5 mm (0.886 in)
Limit 5.0 mm (0.197 in)
Battery Type and capacity 12 V - 48 AH (55D 23L)
CCA 390A
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.