2016 Subaru BRZ Series.HyperBlueFACTORY OEM SERVICE PROCEDURE

Work Support: Notes

  1. Steering zero point calibration
    CAUTION:
    • Always perform a steering zero point calibration after replacing the steering column assembly or power steering computer assembly, or when there is a difference between the right and left steering force.
    • When C1516 (torque sensor zero point calibration not finished) is recorded, please delete the diagnosis code as torque sensor zero point calibration is unable to be performed in this case. (Refer to CHECKING/CLEARING DIAGNOSTIC CODESΒ  )
    • When C1526 (Resolver calibration not finished) is recorded, please delete the diagnosis code as rotation angle sensor output calibration is unable to be performed in this case. (Refer to CHECKING/CLEARING DIAGNOSTIC CODESΒ  )