2013 Subaru Outback Base, Automatic CVT TransFACTORY OEM SERVICE PROCEDURE

Non-Turbo Model

WARNING: This page is about a different car, the 2013 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
  1. Open the front hood.
  2. Disconnect the ground cable from battery.
  3. Remove the air intake boot assembly. < Refer to REMOVAL , Air Intake Boot. >
  4. Disconnect the transmission harness connector and terminal.
    Fig 1: Identifying Transmission Harness Connector And Terminal
    G08563847Courtesy of SUBARU OF AMERICA, INC.
  5. Remove the pitching stopper.
    Fig 2: Identifying Pitching Stopper
    G04994045Courtesy of SUBARU OF AMERICA, INC.
  6. Remove the pitching stopper bracket.
    Fig 3: Locating Pitching Stopper Bracket Mounting Bolts
    G08563849Courtesy of SUBARU OF AMERICA, INC.
  7. Remove the engine ground terminal.
    Fig 4: Locating Engine Ground Terminal Mounting Bolts
    G08563850Courtesy of SUBARU OF AMERICA, INC.
  8. Remove the starter. < Refer to REMOVAL , Starter. >
  9. Separate the torque converter clutch from the drive plate.
    CAUTION:
    • Be careful not to damage the mounting bolts.
    • Be careful not to drop bolts into the converter case.
    1. Remove the service hole plug.
    2. Remove the bolts which hold the torque converter clutch assembly to the drive plate.
      Fig 5: Placing Wrench On Crank Pulley Bolt
      G08563851Courtesy of SUBARU OF AMERICA, INC.
    3. Place the wrench on the crank pulley bolt, and remove all the bolts while rotating the crank pulley a little bit at a time.
    4. Make sure the torque converter moves freely by rotating with finger through the starter installation hole.
  10. Attach the ST to the converter case.

    ST 498277200 STOPPER SET

    Fig 6: Attaching ST To Converter Case
    G08563852Courtesy of SUBARU OF AMERICA, INC.
  11. Remove the ATF level gauge and oil charge pipe.
    NOTE: Plug the opening to prevent entry of foreign particles into the transmission fluid.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.