2012 Subaru Outback F4-2.5L SOHCFACTORY OEM SERVICE PROCEDURE

Refrigerant Recovery Procedure

REFRIGERANT RECOVERY PROCEDURE

PROCEDURE

Preparation tool:
Manifold gauge set
Refrigerant recovery system

CAUTION:
- During operation, be sure to wear protective goggles and protective gloves.
- Connect the refrigerant recovery system with the manifold gauge set to discharge the refrigerant from the A/C system and recycle the gas.
- When recycling the discharged refrigerant, keep service cans on hand. Because the recovery rate with the recovery system is approx. 90%, service cans are necessary to charge the refrigerant.
- Follow the detailed operation procedure described in the operation manual attached to the refrigerant recovery system.


Factory service manual diagram





1. Perform compressor oil return operation. Procedures
2. Stop the engine.
3. Attach the manifold gauge set.
1. Check that all valves are fully closed.
2. Install the low/high pressure hoses to the service ports on the low/high pressure sides of the vehicle respectively.

CAUTION: Confirm that the connections are secure.

3. Connect the center hose to the refrigerant recovery system.

4. Follow the operation manual attached to the refrigerant recovery system to collect the refrigerant.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.