2009 Subaru Legacy GT spec.BFACTORY OEM SERVICE PROCEDURE

Intake Manifold: Installation

  1. Install the intake manifold onto cylinder heads.
    NOTE: Use a new gasket.

    Tightening torque:Β 

    25 N.m (2.5 kgf-m, 18.4 ft-lb)Β 

    Fig 1: Locating Tumble Generator Valve Assembly And Bolts
    G05340088Courtesy of SUBARU OF AMERICA, INC.
  2. Connect the fuel delivery hose, fuel return hose, and evaporation hose. Refer to INSTALLATIONΒ , Fuel Delivery, Return and Evaporation Lines.
    NOTE: If fuel hoses or clamps are damaged, replace them with new parts.