2008 Subaru Outback Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Ignition Key Lock: Inspection

WARNING: This page is about a different car, the 2006 Subaru Outback and 2006 Subaru Legacy. However, it is still accessible from the selected car via links, so may be relevant.
  1. Remove the instrument panel lower panel.
  2. Remove the lower column cover.
  3. Unfasten the fixing clip which secures harness, and then disconnect the connector of the ignition switch from body harness.
  4. Turn the ignition key plate to each position and check the continuity between terminals of ignition connector.
    Fig 1: Identifying Ignition Connector Terminals
    G05022828
    RESISTANCE SPECIFICATION

    Switch position Terminal No. Standard
    LOCK - -
    ACC No. 3 and No. 4 Less than 1 Ξ©
    ON No. 3, No. 1 and No. 4 No. 3 and No. 6 Less than 1 Ξ©
    ST No. 3 and No. 1 No. 3, No. 2 and No. 6 Less than 1 Ξ©

    If NG, replace the ignition switch.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.