2008 Subaru Outback Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Starting System & Charging System (H4SO): Generator: Inspection: Diode

CAUTION: There is the possibility of damaging the diodes if a mega-tester (used to measure high voltages) or a similar measuring instrument is used. Never use a mega tester or equivalent for this test.
  1. Check the positive diode

    Check for continuity between the diode lead and positive side heat sink. If resistance is 1 Ξ© or less only in the direction from the diode lead to the heat sink, the positive diode is OK.

    Fig 1: Checking Continuity Between Diode Lead And Positive Side Heat Sink
    G05339794Courtesy of SUBARU OF AMERICA, INC.
  2. Check negative diode

    Check for continuity between the negative side heat sink and diode lead. If resistance is 1 Ξ© or less only in the direction from the heat sink to the diode lead, the negative diode is OK.

    Fig 2: Checking Continuity Between Negative Side Heat Sink And Diode Lead
    G05339795Courtesy of SUBARU OF AMERICA, INC.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.