Ignition Timing: Testing and Inspection

2007 Subaru Forester F4-2.5L DOHC TurboSECTION Testing and Inspection
Ignition Timing

INSPECTION
1. Before checking the ignition timing, check the following item:
1. Check the air cleaner element is free from clogging, spark plugs are in good condition, and hoses are connected properly.
2. Check the malfunction indicator light does not illuminate.
2. Warm-up the engine.
3. Stop the engine, and turn the ignition switch to OFF.
4. Insert the cartridge to Subaru Select Monitor.
5. Connect the Subaru Select Monitor to data link connector.





6. Turn the ignition switch to ON and Subaru Select Monitor to ON.
7. Select (Each System Check) in Main Menu.
8. Select (Engine Control System) in Selection Menu.
9. Select (Current Data Display & Save) in Engine Control System Diagnosis.
10. Select (Data Display) in Data Display Menu.
11. Start the engine and check the ignition timing at idle speed.
Ignition timing [BTDC/rpm]:
17° ± 10°/700
If the timing is not correct, check the ignition control system. Refer to Engine Control System.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.