2007 Subaru B9 Tribeca BaseFACTORY OEM SERVICE PROCEDURE

DTC P0607 Control Module Performance: Wiring Diagram

Fig 1: Control Module Performance - Wiring Diagram
G05346116Courtesy of SUBARU OF AMERICA, INC.
DIAGNOSIS PROCEDURE

Step Check Yes No
1 CHECK INPUT VOLTAGE FROM ECM. 
  1. Turn the ignition switch to ON.
  2. Measure the voltage between ECM and chassis ground.

    Connector & terminal 

    (B134) No. 7(+) - Chassis ground (-): 

    (B135) No. 2 (+) - Chassis ground (-): 

Is the voltage 10 - 13 V? Go to step 2  . Repair the open or ground short circuit of power supply circuit.
2 CHECK INPUT VOLTAGE FROM ECM. 
  1. Start the engine.
  2. Measure the voltage between ECM and chassis ground.

    Connector & terminal 

    (B134) No. 7 (+) - Chassis ground (-): 

    (B135) No. 2 (+) - Chassis ground (-): 

Is the voltage 13 - 15 V? Go to step 3  . Repair the open or ground short circuit of power supply circuit.
3 CHECK ECM GROUND HARNESS. 
Measure the voltage between ECM and chas ground.
Connector & terminal 
(B134) No. 3 (+) - Chassis ground (-): 
(B134) No. 5 (+) - Chassis ground (-): 
(B137) No. 1 (+) - Chassis ground (-): 
(B137) No. 2 (+) - Chassis ground (-): 
(B137) No. 3 (+) - Chassis ground (-): 
(B137) No. 7 (+) - Chassis ground (-): 
Is the voltage less than 1 V? Replace the ECM. <Ref. to ENGINE CONTROL MODULE (ECM) . > Repair the following item.
  • Further tighten the engine ground terminal.
  • Poor contact in ECM connector
  • Poor contact of coupling connector
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.