2006 Subaru Outback RFACTORY OEM SERVICE PROCEDURE

Switch Assembly

  1. Return spring check

    Make sure the plunger returns to its original position immediately after pressed-in then released.

    Fig 1: Checking Plunger Returns
    G05017435
  2. Magnet switch continuity test

    Be sure there is continuity between the terminals S and M, and between terminal S and ground. Use a circuit tester.

    Also check to be sure there is no continuity between terminal M and B.

    Terminal / Resistance: 

    S - M/1 Ω or less 

    S - Ground/1 Ω or less 

    M - B/1 MΩ or more 

    Fig 2: Checking Continuity Between Terminals S And M
    G04997954
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.