2006 Subaru B9 Tribeca BaseFACTORY OEM SERVICE PROCEDURE

Fuel Sub Level Sensor: Removal

WARNING:
  • Place "NO FIRE" signs near the working area.
  • Be careful not to spill fuel on the floor.
  1. Drain fuel. < Refer to DRAINING FUELΒ , PROCEDURE, FUEL. >
  2. Remove the second seat. < Refer to REMOVAL , Second-row Seats. >
  3. Remove the service hole cover.
    Fig 1: Locating Service Hole Cover
    G05031085Courtesy of SUBARU OF AMERICA, INC.
  4. Disconnect the connector from the fuel sub level sensor.
    Fig 2: Locating Fuel Sub Level Sensor Connector
    G05016927Courtesy of SUBARU OF AMERICA, INC.
  5. Disconnect the quick connector, and then disconnect the fuel delivery hose, return hose and jet pump hose. < Refer to REMOVALΒ , FUEL DELIVERY, RETURN AND EVAPORATION LINES. >
  6. Remove the nuts and bolts which install fuel sub level sensor on fuel tank.
    Fig 3: Identifying Delivery And Jet Pump Hose
    G05031111Courtesy of SUBARU OF AMERICA, INC.
  7. Remove the fuel sub level sensor.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.