Electrical Specifications
AT SHIFT LOCK CONTROL SYSTEM CONNECTOR TERMINALS VOLTAGE CONDITIONS
| Contents | To Connector No. | Terminal No. | Input/Output signal |
|---|---|---|---|
| Measured value and measuring conditions | |||
| Battery power supply | B280 | 2 | 9 - 16 V |
| Ignition power supply | B281 | 19 | 10 - 15 V when ignition switch is at ON or START. |
| Ignition power supply | B281 | 10 | 10 - 15 V when ignition switch is at ACC or ON. |
| Inhibitor Switch ("P" range) | B281 | 5 | 0 V when select lever is in "P" range. 9 - 16 V when select lever is in other ranges than "P" range. |
| Stop light switch | B281 | 9 | 9 - 16 V when stop light switch is ON. 0 V when stop light switch is OFF. |
| "P" range switch | B281 | 6 | 0 V when select lever is in "P" range. 9 - 16 V when select lever is in other ranges than "P" range. |
| Shift lock solenoid signal | B280 | 9 | 8.5 - 16 V when shift lock is released. 0 V when shift lock is operating. |
| Key warning switch signal | B281 | 20 | 9 - 16 V when key is inserted. 0 V when key is removed. |
| Key lock solenoid signal | B280 | 3 | Pulse is output when switching key lock between locked and unlocked. 0 V at other conditions than above. |
| Ground | B280 | 4 | - |
| Ground | B280 | 13 | - |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.