2004 Subaru Baja Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Inhibitor Switch: Installation

  1. Connect the inhibitor switch harness connector to inhibitor switch.
  2. Install the inhibitor switch to transmission case.
    Fig 1: Installing Inhibitor Switch To Transmission Case
    G00917507Courtesy of SUBARU OF AMERICA, INC.
  3. Move the range select lever to neutral position.
  4. Using the ST, tighten the bolts of inhibitor switch. ST 499267300 STOPPER PIN
    1. Tightening torque: 3.5 N.m (0.36 kgf.m, 2.6 ft.lb)Β 
    Fig 2: Tightening Bolts Of Inhibitor Switch
    G00917508Courtesy of SUBARU OF AMERICA, INC.
  5. Install the select cable to range select lever.
  6. Install the plate assembly to transmission.
    1. Tightening torque: T: 25 N.m (2.5 kgf.m, 18.1 ft.lb)Β 
    Fig 3: Installing Plate Assembly To Transmission
    G00917509Courtesy of SUBARU OF AMERICA, INC.
  7. Install the washer and snap pin to range select lever.
    Fig 4: Installing Washer & Snap Pin To Range Select Lever
    G00917510Courtesy of SUBARU OF AMERICA, INC.
  8. Install the front and center exhaust pipes. (Non-TURBO model)

    Except 2.5 L U5 model

    Refer to INSTALLATION , Front Exhaust Pipe.

    2.5 L U5 model

    Refer to INSTALLATION , Front Exhaust Pipe.

    3.0 L model

    Refer to INSTALLATION , Front Exhaust Pipe.

  9. Install the center exhaust pipe. (TURBO model) Refer to INSTALLATION , Center Exhaust Pipe.
  10. Lower the vehicle.
  11. Install the inhibitor switch connector from stay.
  12. Connect the inhibitor switch connector.
    Fig 5: Installing Inhibitor Switch Connector From Stay
    G00917511Courtesy of SUBARU OF AMERICA, INC.
  13. Install the air cleaner case or air intake chamber. (Non-TURBO model)

    Except 2.5 L U5 model

    Refer to INSTALLATION , Air Cleaner Case.

    2.5 L U5 model

    Refer to INSTALLATION , Air Intake Chamber.

    3.0 L model

    Refer to INSTALLATION , Air Intake Chamber.

  14. Install the intercooler. (TURBO model) Refer to INSTALLATION , Intercooler.
  15. Inspect the inhibitor switch. Refer to INSPECTIONΒ .
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.