Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2002 Subaru Forester BaseFACTORY OEM SERVICE PROCEDURE
Section 104 (HVAC): Compressor: Removal
WARNING: This page is about a different car, the 2003 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
- Perform the compressor oil return operation. Refer to OPERATIONΒ , Compressor Oil.
- Turn the A/C switch OFF and stop the engine.
- Using the refrigerant recovery system, discharge refrigerant. Refer to OPERATIONΒ , Refrigerant Recovery Procedure.
- Disconnect the ground cable from battery.
- Remove the V-belt. Refer to REMOVAL , V-belt.
- Remove the generator. Refer to REMOVAL , Generator.
- Remove the low-pressure hose and high-pressure hose.
- Disconnect the compressor harness from body harness.
- Loosen the bolts to remove compressor bracket.
- Remove the bolts and then separate compressor and bracket.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.