2001 Subaru Outback Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Compressor Oil: Operation

WARNING: This page is about a different car, the 2001 Subaru Impreza. However, it is still accessible from the selected car via links, so may be relevant.
  1. Prior to opening the refrigerant system for repairs (except compressor seizure) the system must be stabilized for correct oil replenishment.
  2. Follow these procedures:
    1. Engine speed set to 1,500 RPM.
    2. A/C "ON".
    3. Air source to recirculate
    4. Blower 4th or high speed position
      • Make sure the air entering the evaporator is above 26.7Β°C (80Β°F).
      • The discharge (high) side pressure must be above 588 kPa (6 kg/cm2 , 85 psi).
    5. Operate the A/C for 10 minutes.
  3. Slowly, discharge the system starting with the high-pressure side until the pressure drops below 345 kPa (3.52 kg/cm2 , 50 psi), then open the low- pressure side.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.