Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1995 Subaru SVX LSiFACTORY OEM SERVICE PROCEDURE
Code 23 - Airflow Sensor
NOTE:
Refer to illustration for ECM connector terminal identification. See Figure
.
- Check ECM input signal for airflow sensor. Turn ignition on. Using a DVOM, check voltage between ECM connector terminal B5 (backprobe) and ground. Voltage should be 0-0.3 volt. Check voltage between ECM connector terminal B6 (backprobe) and ground. Voltage should not exist. Check voltage between ECM connector terminal A11 (backprobe) and ground. Voltage should be 10-13 volts.
- With engine idling, check voltage between ECM connector terminal B5 and ground. Voltage should be 0.8-1.2 volts. Check voltage between ECM connector terminal B6 and ground. Voltage should not exist. Check voltage between ECM connector terminal A11 and ground. Voltage should be 13-14 volts.
- If voltage is as specified in previous steps, check ECM connector terminals for good contact. Repair as necessary. If connector terminals are okay, replace ECM. If voltage is not as specified in previous steps, turn ignition off. Disconnect ECM and airflow sensor connectors.
- Using an ohmmeter, check resistance between ECM connector terminal A11 and sensor connector terminal No. 3 (Black/Red wire), between ECM connector terminal B4 and sensor connector terminal No. 1 (Red wire), between ECM connector terminal B5 and sensor connector terminal No. 4 (White wire), and between ECM connector terminal B6 and sensor connector terminal No. 2 (Black wire).
- Resistance should be zero ohms for all circuits. If resistance is not as specified, repair appropriate circuit as necessary. If resistance is as specified, replace airflow sensor.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.