Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1995 Subaru SVX LSiFACTORY OEM SERVICE PROCEDURE
Code 35 - Purge Control Solenoid Valve
NOTE:
Refer to illustration for ECM connector terminal identification. See Figure
.
- Turn ignition on. Using a DVOM, check voltage between ECM connector terminal D14 (backprobe) and ground. Voltage should be 10 volts or greater. If voltage is not as specified, go to next step. If voltage is as specified, go to step 4).
- Turn ignition off. Disconnect ECM and main relay connectors. Using an ohmmeter, check resistance between ECM connector terminal D14 and main relay connector terminal No. 1 (Black/White wire). Resistance should be zero ohms. If resistance is as specified, go to next step. If resistance is not as specified, repair circuit as necessary.
- Turn ignition on. Using a DVOM, check voltage between ground and main relay connector terminals No. 1 (Black/White wire) and No. 2 (Brown/Black wire). Voltage should be 10 volts or greater at each terminal. If voltage is as specified, replace main relay. If voltage is not as specified, repair appropriate circuit as necessary.
- Turn ignition on. Using a DVOM, check voltage between ECM connector terminal D6 (backprobe) and ground. Voltage should be 7 volts or greater. If voltage is not as specified, go to next step. If voltage is as specified, check ECM connector terminals for good contact. Repair as necessary. If connector terminals are okay, replace ECM.
- Turn ignition off. Remove collector and disconnect purge control solenoid valve connector. Using an ohmmeter, check resistance between ECM connector terminal D6 and solenoid valve connector terminal No. 2 (White/Red wire). Resistance should be zero ohms. If resistance is as specified, replace purge control solenoid valve. If resistance is not as specified, repair circuit as necessary.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.